OBR

From Updox API
Jump to: navigation, search

Requirements for messages outbound from Updox are dependent on the receiving implementation/system, and are negotiated during the implementation phase. The following describes a typical (default) implementation.

OBR Outbound

Sequence Length Data Type Req/Optional/Not Used/Notes Element Name
1 4 SI R Set ID – OBR
2 75 EI NU Placer Order Number
3 75 EI NU Filler Order Number
4 200 CE R - UPDX^(Title as entered in Updox) Universal Service ID
5 2 ID NU Priority
6 26 TS NU Requested Date/time
7 26 TS R Observation Date/Time
8 26 TS NU Observation End Date/Time
9 20 CQ NU Collection Volume
10 60 XCN NU Collector Identifier
11 1 ID NU Specimen Action Code
12 60 CE NU Danger Code
13 300 ST R - Notes as entered in Updox Relevant Clinical Info.
14 26 TS NU Specimen Received Date/Time
15 300 CM NU Specimen Source
16 80 XCN NU Ordering Provider
17 40 XTN NU Order Callback Phone Number
18 60 ST NU Placer field 1
19 60 ST NU Placer field 2
20 60 ST NU Filler Field 1
21 60 ST NU Filler Field 2
22 26 TS R - Timestamp of Import Results Rpt/Status Chng – Date/Time
23 40 CM NU Charge to Practice
24 10 ID NU Diagnostic Serv Sect ID
25 1 ID NU Result Status
26 400 CM NU Parent Result
27 200 TQ NU Quantity/Timing
28 150 XCN O - Provider, if chosen in Updox Result Copies To
29 150 CM NU Parent
30 20 ID NU Transportation Mode
31 300 CE NU Reason for Study
32 200 CM NU Principal Result Interpreter
33 200 CM NU Assistant Result Interpreter
34 200 CM NU Technician
35 200 CM NU Transcriptionist
36 26 TS NU Scheduled Date/Time
37 4 NM NU Number of Sample Containers
38 60 CE NU Transport Logistics of Collected Sample
39 200 CE NU Collector’s Comment
40 60 CE NU Transport Arrangement Responsibility
41 30 ID NU Transport Arranged
42 1 ID NU Escort Required
43 200 CE NU Planned Patient Transport Comment