OBX

From Updox API
Revision as of 05:56, 10 April 2018 by Mwitting (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Requirements for messages outbound from Updox are dependent on the receiving implementation/system, and are negotiated during the implementation phase.

OBX Outbound

Sequence Length Data Type Req/Optional/Not Used/Notes Element Name
1 4 SI R Set ID – Obx
2 2 ID R - ED Value Type
3 590 CE R Observation Identifier
4 20 ST NU Observation Sub-Id
5 LONG ST R - '^application^pdf^Base64^(PDF Data)' Observation Value
6 60 CE NU Units
7 10 ST NU Reference Range
8 5 ID NU Abnormal Flags
9 5 NM NU Probability
10 2 ID NU Nature of Abnormal Test
11 1 ID NU Observation Result Status
12 26 TS R - 'F' Last Observation Normal Values
13 20 ST NU User Defined Access Checks
14 26 TS R - Timestamp of import Date/Time of the Observation
15 60 CE R - EHR User ID of Updox User Producer’s Id
16 80 XCN R - EHR User ID of Updox User Responsible Observer
17 80 CE NU Observation Method